Go to file
2018-05-31 19:09:14 +02:00
fakeStation now act like a real station 2018-05-26 20:00:37 +02:00
gateway EL POST FONCTIONNAR 2018-05-30 14:52:00 +02:00
LoRa_test modif 2018-05-23 08:55:25 +02:00
LoRaReceiver-struct modif 2018-05-23 08:55:25 +02:00
numero_passerelle changes 2018-05-14 11:59:13 +02:00
postToServer its now like a real station 2018-05-31 19:09:14 +02:00
WebServer added pritning messages for knonwing the state of the gateway on serial 2018-05-26 15:21:10 +02:00
.gitattributes 🍭 Added .gitattributes 2018-03-13 12:17:52 +01:00
README.md added commentary 2018-05-02 09:19:53 +02:00

passerelleLoRa

Projet BTS SNIR 2ème année Gateway between a weather MicroStation using LoRa modulation and a web server. This depo is segmented in different programs for arduino using ATMEGA328P and SAMD21.

Attention !

Because we're using two arduino shields using SPI communication, we need to select a chip select for each shield. I decided to use D11 for the Ethernet shield (10 for the LoRa, 4 for the SD).

To do this, edit w5100.h in the default ethernet librairy in the installation folder of your arduino IDE (on windows, in administrator mode C:\Program Files (x86)\Arduino\libraries\Ethernet\src\utility\w5100.h)

On this case, you need to change this line #define ETHERNET_SHIELD_SPI_CS 10 to #define ETHERNET_SHIELD_SPI_CS 11